Home Categories Send inquiry

steam generator NBS-36KW-0 09Mpa amd superheater NBS-36KW-900℃

Steam is dry saturated only when it has all of its latent heat, and its dryness is 1. Based on the influence of steam dryness on calorific value, the measurement of dryness value can estimate or calculate its dryness by measuring the energy or heat contained in steam at a specific pressure through simple calorimetry. If the steam contains 10% water by mass, the steam has a dryness of 90%, that is, the dryness is 0.9. Therefore, the actual wet steam evaporation is not the hfg shown on the steam table, but the actual evaporation is the product of dryness x and hfg.Dryness = actual evaporation stew/evaporation stew Since the state of condensate in steam is uncertain, the sampling position of steam dryness is in the middle, bottom, or top of the steam supply pipe. Due to the moisture film on the inner wall of the pipe or the different states of condensate accumulation and suspended water droplets at the bottom of the steam pipe, the dryness error may exceed 50%. The sampling position of the steam dryness after the high-efficiency steam-water separator is no longer strict. The dryness after the high-efficiency steam-water separator is increased to dry saturated steam, and the total steam value contained in the steam should be equal to the steam value under the corresponding pressure. And use this to determine the treatment effect of the high-efficiency steam-water separator. 1. Technical parameters of steam generator: Model: NBS-24KW-0.09Mpa Rated evaporation capacity: 32kg/h Rated working pressure: 0.09Mpa   Rated steam temperature: 119℃ Main steam diameter (DN): 15 Safety valve diameter (DN): 15 Inlet diameter (DN): 15 Drain valve diameter (DN): 15 Dimensions (mm): 835×620×1000 (subject to actual size) Weight (KG): 125KG (subject to actual weight) 2. Design and structure of steam generator (1) Comply with Chinese steam generator standard (2) Low water level shutdown protection (3) Overcurrent shutdown protection   3. The main electrical appliances and control system of the steam generator (1) The main electric heater is selected from joint venture products (2) The components of the main electrical control cabinet are all selected from well-known domestic brands (3) Pressure limit automatic control device (4) Safety valve automatic discharge device (5) Power phase failure protection function 4. The main components of the steam generator

No.

Name

Specification

Quantity

One

Electric steam generator

NBS-24KW-0.7mpa

1

Two

Liner

 stainless steel

1

Three

Cabinet

paint

1

Four

Safety valve

A28Y-16C DN15

1

Five

Pressure gauge

Y60 -ZT-0.25MPA

1

Six

Heating tube

12KW

1

Seven

Heating tube

12KW

1

Eight

Liquid level display gauge

17cm

1

Nine

High pressure scroll pump

750W

1

Ten

Liquid Level Relay

AFR-1 220VAC

1

Eleven

Pressure Controller

LP10

1

Twelve

Water tank

float

1

Thirteen

AC contactor

4011

2

Fourteen

Check valve

thread port

2

Fifteen

Drain valve

thread port

1

   

Superheater NBS-36KW-900℃ reference technical parameters

 1. Technical parameters of steam generator: Model: NBS-24KW-900℃ Rated working pressure: 0.09Mpa Design temperature: 900°C Energy consumption: 24KW/H Fuel: Electricity Power supply: 380v,50Hz Product weight (kg): 368kg (subject to actual weight) Dimensions (mm): 1480*1500*900 horizontal (subject to physical size)   2. The main components of the steam generator  

No.

Name

Specification

Quantity

Brand

One

electric steam superheater

NBS-24KW

1

Nobeth

Two

Liner

 stainless steel

1

Nobeth

Three

 Cabinet

 paint

1

Nobeth

Four

Safety valve

A48Y-16C DN25

1

Guangyi

Five

 Pressure gauge

Y100 -0.25MPA

1

Hongqi

Six

Temperature Sensor

/

2

/

Seven

Steam outlet shut-off valve

DN20 flange connection

2

Peilin