Home Categories Send inquiry

Q:How to troubleshoot electric heating steam generator


A:
1. The power does not work or the heating is very slow: check whether the power supply is out of phase, whether the ‘zero’ line is connected, and whether the voltage is too low.
2. The AC contactor jumps back and forth during work: Check whether the power supply voltage is too low; check whether the probe wire is in poor contact, whether the grounding wire on the body is loose, and whether the wiring is correct.
3. When the air pressure rises to the set value or falls to the set value, the heating AC contactor bounces back and forth: it is the pressure controller that is in poor contact.
4. If you turn on the machine for the first time or after it is not in use, if you find that the green light is on, but the water pump is stuck, you should stop it immediately, turn on the rear end of the water pump, and rotate the shaft.
5. The water pump keeps adding water: check whether the probe circuit screw is in good condition; remove the dirt on the probe or replace the probe.
6. If the work was normal the day before, and the water in the furnace was found to be full just after turning on the machine the next day: it was because the residual gas was not discharged when the machine was turned off the day before, and after the air pressure cooled down, the furnace formed a negative pressure and the water in the water tank was sucked into the furnace by itself. At this time, as long as you open the drain valve and let off the excess water, you can restart the machine.

wet slime in the mine
Nobeth electric heating steam generator has the following advantages:
1. The shell of the product is made of thickened steel plate and special painting process, which is exquisite and durable, and has a very good protection effect on the internal system. You can also customize the color according to your needs.
2. The interior adopts the design of water and electricity separation, which is scientific and reasonable, and the functional modules can be operated independently to enhance the stability during operation and prolong the service life of the product.
3. The protection system is safe and reliable, with multiple safety alarm control mechanisms for pressure, temperature, and water level, which can be monitored automatically, with multiple guarantees, and is equipped with high-safety, high-quality safety valves to protect production safety in all directions.
4. The internal electronic control system can be operated with one button, the temperature and pressure can be controlled, the operation is convenient and fast, saving a lot of time and labor costs, and improving production efficiency.
5. Microcomputer automatic control system, independent operation platform and human-computer interactive terminal operation interface can be developed, 485 communication interface is reserved, and with 5G Internet of Things communication technology, local and remote dual control can be realized.
6. The power can be adjusted in multiple gears according to the needs, and different gears can be adjusted for different production needs, saving production costs.
7. The bottom is equipped with universal wheels with brakes, which can move freely, and can also customize the skid-mounted design to save installation space.
Nuobeisi electric heating steam generator can be widely used in medical, pharmaceutical, biological, chemical, food processing and other industries such as heat energy special supporting equipment, especially for constant temperature evaporation. preferred device.